1 DATECS
OD 07.01.02/v.1
стр. 62 от 65
EP_2000_PM_EN_V.1.60_Nov.2009.doc
sY
Size (multiplication) in vertical direction.
From
1
to
16
.
Attr
Print attributes. One byte from
0
to
255
.
Each bit of
Attr
indicates the following:
Bit Function Value 0 Value 1
0
Font size
А
(12x24 or
24x24)
B
(9x16 or
16x16)
1
Not used
2
Not used
3
Bold Enabled Disabled
4
Not used
5
Not used
6
Not used
7
Not used
Di
Data.
Bytes with ASCII codes below
20h
are ignored.
X
and
Y
coordinates are
xL+256*xH
and
yL+256*yH
.
The currently active page direction, country and code table are used.
From all print attributes only BOLD is used.
After every printed symbol
X
coordinate is automatically increased by
symbol width + character space, multiplied by
sX
.
If some part of the symbol is not in the selected page area, the symbol is
not printed.
The command is executed in page mode only.
The command is supported in firmware
version 1.51
or higher.